Emzer

Showing all 5 results

  • Emzer EMSCOPE EMI Receiver

    The Emzer EMSCOPE is a New double EMI-Test Receiver according to CISPR-16-1-1, which can be optionally integrated with a 16-A LISN, that fully embodies the measurement of common and differential mode conducted emissions. It combines Two simultaneous EMI Receivers with PK, QPK and AVG detectors for both channels according to CISPR 16-1-1. It has an optional 16-A single-phase Dual-Port V- network Line Impedance Stabilization Network (LISN), two Transient Limiters and  Integrated Test software. Both channels can be run in parallel and real time, showing an important reduction of the measurement time when compared to any other option. Additionally, thanks to this feature, EMSCOPE can show the measurement of the L-G and N-G Conducted Emissions (as defined in CISPR 16), or the common-mode and differential-mode (modal) emissions with any of the three detectors. Modal-emission measurements are fundamental to know the dominant mode and to implement the suitable power-line filter accordingly, using fewer components and getting a more cost-effective design.

    • Frequency Range: 9kHz to 30MHz
    • Upgradeable to 110MHz
    • Peak, Quasi-Peak and Average Detectors
    • Six Simultaneous Measurements
    • Channels: 2
    • Transient Limits: 2
    • Internal 1P LISN
    • Optional Time Domain Analysis (Oscilloscope mode)
    • Integrated Software
    • Fibre and Ethernet interfaces
  • Emzer EMSCOPE RX2 EMI Receiver

    The Emzer EMSCOPE  RX2 is a New double EMI-Test Receiver according to CISPR-16-1-1.  It combines Two simultaneous EMI Receivers with PK, QPK and AVG detectors for both channels according to CISPR 16-1-1. It has an optional 16-A single-phase Dual-Port V- network Line Impedance Stabilization Network (LISN), two Transient Limiters and  Integrated Test software. Both channels can be run in parallel and real time, showing an important reduction of the measurement time when compared to any other option. Additionally, thanks to this feature, EMSCOPE RX2 can show the measurement of the L-G and N-G conducted emissions (as defined in CISPR 16), or the common-mode and differential-mode (modal) emissions with any of the three detectors. Modal-emission measurements are fundamental to know the dominant mode and to implement the suitable power-line filter accordingly, using fewer components and getting a more cost-effective design.

    • Frequency Range: 9kHz to 30MHz
    • Upgradeable to 110MHz
    • Peak, Quasi-Peak and Average Detectors
    • Six Simultaneous Measurements
    • Channels: 2
    • Transient Limits: 2
    • Optional Time Domain Analysis (Oscilloscope mode)
    • Integrated Software
    • Fibre and Ethernet interfaces
  • Emzer EMSCOPE RX4LZ2 EMI Receiver

    The Emzer EMSCOPE RX4 is a New  EMI-Test Receiver according to CISPR-16-1-1. which can be optionally integrated
    with a 16-A LISN, that fully embodies the measurement of common and differential mode conducted emissions. It combines Four simultaneous EMI Receivers with PK, QPK and AVG detectors for all channels according to CISPR 16-1-1. It has an optional 16-A single-phase Dual-Port V- network Line Impedance Stabilization Network (LISN), four Transient Limiters and  Integrated Test software. All channels can be run simultaneously and real time, showing an important reduction of the measurement time when compared to any other option. Additionally, thanks to this feature, EMSCOPE RX4 can show the measurement of the L-G and N-G Conducted Emissions (as defined in CISPR 16), or the common-mode and differential-mode (modal) emissions with any of the three detectors. Modal-emission measurements are fundamental to know the dominant mode and to implement the suitable power-line filter accordingly, using fewer components and getting a more cost-effective design.

    • Frequency Range: 9kHz to 30MHz
    • Upgradeable to 110MHz
    • Three Phase EUT
    • Peak, Quasi-Peak and Average Detectors
    • Six Simultaneous Measurements
    • Channels: 4
    • Transient Limits: 4
    • Optional Time Domain Analysis (Oscilloscope mode)
    • Integrated Software
    • Fibre and Ethernet interfaces
  • Emzer LINZ Line Impedance Stabilization Network (LISN)

    LIZN is the new EMZER’s 16-A single-phase Dual Port V-network Line Impedance Stabilization Network (LISN) that has been optimally designed and manufactured to be compliant to CISPR 16-1-2 International Standard for the measurements of the
    Conducted Electromagnetic Interference.

    • Fully compliant to CISPR 16-1-2 and MIL-STD-461 standards
    • Frequency Range: 9 kHz – 30 MHz
    • AMN Impedance: 50 Ohms || (50 uH + 5 Ohms)
    • Network impedance: 50 Ohms
    • 16-A Single Phase Dual Port
    • Common-Mode  and Differential-Mode Conducted Emissions
    • Simultaneous Measurement of Line and Neutral
  • Emzer EMZ10-200M Transient Limiter

    The EMZ10-200M Transient Limiter  protects the input of Spectrum Analyzers and Measurement Receivers. It can be used in combination with a Line Impedance Stabilization Network (EMZER’s LIZN).

    • Frequency Range: 9 kHz – 200 MHz
    • Insertion Lose: 10 dB ± 1dB
    • Maximum Input Power: 5W (37 dBm, 144 dB?V) at 25ºC
    • Input/Output Impedance: 50 ?
Top