NanoBrook Particle & Zeta Potential Analysis

Showing all 5 results

  • Brookhaven NanoBrook Partical Sizing & Zeta Potential Platform

    The Brookhaven Instruments NanoBrook Series is a Configurable Platform for Particle Sizing and Zeta Potential Measurements. The NanoBrook Series Size and Zeta Potential Analyzers incorporate all you need for fast, routine, sub-micron measurements of size and zeta potential. Based on the principles of Dynamic Light Scattering (DLS) for Particle Sizing and distribution, and based on doppler Velocimetry (electrophoretic light scattering or ELS) for Zeta Potential measurement, most measurements only take a minute or two. The instrument also includes Phase Analysis Light Scattering (PALS) measurements for samples with low mobilities.

    Features:

    • Dynamic Light Scattering (DLS)
    • Rapid and Accurate Nanoparticle size distributions
    • Multimodal & Unimodal size distribution software
    • ISO 13321 and ISO 22412 compliant results
    • Phase Analysis Light Scattering (PALS)
    • Electrophoretic Light Scattering (ELS)
    • Molecular Weight determination
    • Disposable Cuvettes
    • USB Interface
    • Easy to Use Benchtop instrument
  • Brookhaven NanoBrook-ZetaPALS Zeta Potential Analyser

    The Brookhaven Instruments NanoBrook ZetaPALS incorporates both traditional ELS and the more sensitive and versatile Phase Analysis Light Scattering (PALS). The high salt tolerance of PALS makes it ideal for samples prepared at physiological ionic strength and above. This NanoBrook is a valuable tool, not only for biopharmaceutical research, but also for oil-recovery where salt concentrations can be several orders of magnitude higher still.

    Features:

    • Zeta Potential
    • Scattering Angle: 15°
    • Phase Angle Scattering
    • Electrophoretic Light Scattering
    • Mobility Range: 10-11 to 10-7 m2 /V•s
    • Zeta Potential Range: -500 mV to 500 mV
    • Maximum Sample Conductivity: 220 mS/cm, covering saline and PBS solutions for proteins
    • Easy to Use Benchtop instrument
    • USB Interface
  • Brookhaven NanoBrook-90Plus Particle Size Analyzer

    The Brookhaven Instruments NanoBrook 90Plus Particle Size Analyzer utilizes Dynamic Light Scattering (DLS) for fast, routine, submicron measurements in research and quality control applications. This is the ideal choice for users who require only DLS particle size measurements but still need rigorous tools for creation of customized reports and multimodal and unimodal size distributions. The instrument can be upgraded later to include Zeta Potential measurement capability.

    Features:

    • Particle Sizing
    • Zeta Potential upgradeable
    • Two Scattering Angles: 15°, 90°
    • Dynamic Light Scattering
    • Size Range: 1 nm to 6 um diameter
    • Concentration Range: 2 ppm to 50 mg/mL
    • Easy to Use Benchtop instrument
    • USB Interface
  • Brookhaven NanoBrook-90Plus PALS Particle Size & Zeta Potential Analyser

    The Brookhaven Instruments NanoBrook 90Plus PALS The Brookhaven NanoBrook 90Plus PALS combines the Particle Sizing capabilities of our 90Plus with the highly sensitive Zeta Potential measurements of our ZetaPALS instrument into one capable package.
    It employs Dynamic Light Scattering (DLS) for size determination and Phase Analysis Light Scattering(PALS) for surface charge evaluation of nanoparticles and other nanomaterials.

    Features:

    • Particle Sizing
    • Zeta Potential
    • Two Scattering Angles: 15°, 90°
    • Dynamic Light Scattering
    • Phase Angle Scattering
    • Electrophoretic Light Scattering
    • Size Range: 1 nm to 10 um diameter
    • Mobility Range: 10-11 to 10-7 m2 /V•s
    • Zeta Potential Range: -500 mV to 500 mV
    • Maximum Sample Conductivity: 220 mS/cm
    • Concentration Range: 2 ppm to 50 mg/mL
    • Easy to Use Benchtop instrument
    • USB Interface
  • Brookhaven NanoBrook-Omni Particle Size and Zeta Potential Analyzer

    The Brookhaven Instruments NanoBrook Omni Particle Size and Zeta Potential Analyzer incorporates all you need for fast, routine, submicron measurements of size and zeta potential. Based on the principles of Dynamic Light Scattering (DLS) for particle sizing, and on Doppler Velocimetry (electrophoretic light scattering, ELS) for Zeta Potential, most measurements only take a minute or two. The instrument also includes Phase Analysis Light Scattering (PALS) measurements for samples with low mobilities (saline, PBS, organic solvents).

    Features:

    • Particle Sizing
    • Zeta Potential
    • Three Scattering Angles: 15°, 90°, & 173°
    • Dynamic Light Scattering
    • Phase Analysis Light Scattering
    • Electrophoretic Light Scattering
    • ISO 13321 and ISO 22412 compliant results
    • Size Range: <0.3 nm to 10 ?m diameter
    • Mobility Range: 10-11 to 10-7 m2 /V•s
    • Zeta Potential Range: -500 mV to 500 mV
    • Maximum Sample Conductivity: 220 mS/cm
    • Concentration Range: 0.1 ppm to 50 mg/mL
    • Easy to Use Benchtop instrument
    • USB Interface
Top